For use in U.S./CanadaUnderwriter's Laboratories Report No. MH760387D15
10CWC Series Woodburning Fireplace87D1504Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use fra
11CWC Series Woodburning Fireplace87D1504An outside air kit is installed in all CWC Series Fire-places. If desired, or if lo
12CWC Series Woodburning Fireplace87D1504FP593SR/C11/20/97 Installing firestop spacer.FP593Nails (4)Firestop SpacerJoist
13CWC Series Woodburning Fireplace87D1504Size of roof hole varies with the type of chimney ter-mination installed. Refer to in
14CWC Series Woodburning Fireplace87D1504used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace
15CWC Series Woodburning Fireplace87D15041. Manville - CERAFORM 126, K=.27, 1/2 inches thick2. MHSC - EH2416, K = .458, 1 inch thick required.
16CWC Series Woodburning Fireplace87D1504COMMON MATERIALS AND FACTORSMATERIAL K*RMINIMUMTHICKNESSEH2416 Common Brick0.4585.01.09 0.50 in.**
17CWC Series Woodburning Fireplace87D1504Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI
18CWC Series Woodburning Fireplace87D15042-583Parts page3/2/99 djt123456128109111514a,b171618OFFLOW1372MHSC reserves the right to make changes in de
19CWC Series Woodburning Fireplace87D1504The following accessories for this appliance are available from your local distributor. Should you need add
2CWC Series Woodburning Fireplace87D1504Read all instructio
20CWC Series Woodburning Fireplace87D1504 Round Top Termination Top used to terminate chimney at roof. RLTSK8 (SK8) (Flashing
21CWC Series Woodburning Fireplace87D1504 Square Chase Termination Square chimney cap use
22CWC Series Woodburning Fireplace87D1504
23CWC Series Woodburning Fireplace87D1504
149 Cleveland Drive • Paris, Kentucky 40361www.mhsc.com
3CWC Series Woodburning Fireplace87D150450" (1270mm)42"(1067mm)35Z\v" (895mm)46" (1168mm)B\,"(16mm)B\," (16mm)Z\x"
4CWC Series Woodburning Fireplace87D1504Insulation methods shown are optional for cold climate, not a requirement for unit operation
5CWC Series Woodburning Fireplace87D1504DRISEBGHBOFFSETCE6 FT.GHAHEARTHFLOORCHIMNEYSECTIONCHIMNEY FLUE EXITELBOWFPC269Chimney Requirements -typ. offse
6CWC Series Woodburning Fireplace87D1504Preplanning an installation is very important to ensure safety and to save time and money.
7CWC Series Woodburning Fireplace87D1504The chimney system is supported by the fireplace for vertical chimney heights less than 30&apo
8CWC Series Woodburning Fireplace87D1504Framing can be constructed before or after the fire-place is set in place, however, most installers bui
9CWC Series Woodburning Fireplace87D1504Since you have already preplanned the chimney run, you should know exactly how the installation