6 44D0060
PRODUCT FEATURES AND SPECIFICATIONS
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DEB20NM MANUAL 28,000 18,000
DEB24NM MANUAL 38,000 20,000
DEB30NM MANUAL 38,000 20,000
DEB20NV MILLI-VOLT 28,000 18,000
DEB24NV MILLI-VOLT 38,000 25,000
DEB30NV MILLI-VOLT 38,000 25,000
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DEB20PM MANUAL 28,000 18,000
DEB24PM MANUAL 38,000 20,000
DEB30PM MANUAL 38,000 20,000
DEB20PV MILLI-VOLT 28,000 20,000
DEB24 PV MILLI-VOLT 38,000 30,000
DEB30PV MILLI-VOLT 38,000 30,000
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
1
/2" W.C. on
natural gas systems operating at higher pressure.
Manual Pressure Milli-Volt Pressure
Regulator Pressure: Setting: 3.0" w.c. Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10
1
/2" w.c. Gas Inlet Pressure: 10
1
/2" w.c.
Min. 5" w.c. Min. 5" w.c.
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manual Pressure Milli-Volt Pressure
Regulator Pressure Setting: 10" w.c. Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13" w.c. Gas Inlet Pressure: Max. 13" w.c.
Min. 11" w.c. Min. 11" w.c.