HWB600/HWB600HB MODELS
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
FOR RESIDENTIAL INSTALLATION
THIS FIREPLACE IS U.L. LISTED FOR USE WITH
THE
"L" SERIES CHIMNEY SYSTEM COMPONENTS.
53D9035. Rev 1 03/03
ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM
HEATER, ANSI/IAS/AGA Z21.11.2, ARE TO BE INSTALLED IN THIS FIREPLACE.
WHEN AN APPROVED ANSI/ISA/AGA Z21.11.2 UNVENTED ROOM HEATER IS INSTALLED IN THIS FIREPLACE, AN H2853
CANOPY MUST ALSO BE INSTALLED.
WARNING: DO NOT OPERATE AN UNVENTED GAS LOG SET IN THIS FIREPLACE WITH THE CHIMNEY REMOVED.
Page view 0
1 2 3 4 5 6 ... 75 76

Summary of Contents

Page 1 - HWB600/HWB600HB MODELS

HWB600/HWB600HB MODELSINSTALLATION, OPERATION AND MAINTENANCE MANUALFOR RESIDENTIAL INSTALLATIONTHIS FIREPLACE IS U.L. LISTED FOR USE WITHTHE "L

Page 2 - CONGRATULATIONS!

MULTIPLE STORY INSTALLATIONMULTIPLE STORY INSTALLATIONATTIC SPACEATTIC SPACESINGLE STORY INSTALLATION WITHSINGLE STORY INSTALLATION WITH POOR  PO

Page 3 - IMPORTANT INFORMATION

10FLOOR PROTECTIONIf this fireplace is installed on a combustible floor, the floor area 20 inches in front of, and 12 inches either sideof the firepla

Page 4 - OPERATION GUIDELINES

52 7/8"52 7/8"27"27"53 1/8"53 1/8"68"68"20"20" FLOOR FLOORCOMBUSTIBLE COMBUSTIBLE 26 3/8&quo

Page 5

12FIREPLACE COMPONENTS53D9035. Rev 1 03/03

Page 6

13FIREPLACE INSTALLATIONLOCATION SELECTIONUnpack and check the fireplace and chimney for damage. If any items have been damaged, report this to yourd

Page 7

CHIMNEY INSTALLATION141. Lay out, cut and frame openings through all ceilings and the roof at the point where the chimney will passthrough. Unless th

Page 8

IMAGINARYCENTER POINT ACTUALCENTER POINTCENTERLINE OF CHIMNEYPLUMB BOBPLUMB LINETABLE 1TABLE 1MINIMUM REQUIRED ROOF OPENINGMINIMUM REQUIRED

Page 9

CHIMNEY OFFSET INSTALLATION16ELBOW INSTALLATIONThe following are important points that should be observed when installing elbows on the fireplace:1. T

Page 10 - INSTALLATION PREPARATION

CHIMNEY OFFSET AND CAP INSTALLATION17CHIMNEY HOUSINGINSTALL ROUND CHIMNEY CAP ORCONTINUE CHIMNEY TO PROPER HEIGHT ANDSTORM COLSTORM COLLARFLASHFLASHIN

Page 11 - FLOOR PROTECTION

CHIMNEY CAP INSTALLATION18MODEL LC CHIMNEY CAPSPECIAL NOTE: The proper height as previously explained is important to assure proper draft and safety.

Page 12

1You have chosen the finest wood burning fireplace available. Your fireplace has been designed foryears of heating and viewing enjoyment. Please tak

Page 13 - FIREPLACE COMPONENTS

CHIMNEY HEIGHT AND OFFSET CHARTS19 17 17 26 1/2 26 1/2 31 3/4 31 3/4 36 36 41 1/4 41 1/4 47 1/4 47 1/4 50 3/4 50 3/4 57 3/4 57 3/4 62

Page 14 - FIREPLACE INSTALLATION

CHIMNEY CAP CHASE INSTALLATION20The preinstalled chimney sections should be no more than 13 inches below the top of the chase. The installationshould

Page 15 - CHIMNEY INSTALLATION

OUTSIDE COMBUSTION AIR PRECAUTIONS & RECOMMENDATIONS21CONCRETE SLAB INSTALLATION  (OPTIONAL OUTSIDE AIR RUNS)INLET GRILLE IN SOFFIT(OVERHANG)

Page 16

OUTSIDE COMBUSTION AIR PRECAUTIONS & RECOMMENDATIONS22OUTSIDE COMBUSTION AIR RECOMMENDATIONS (CONTINUED)1. Extremely long runs and numerous turns

Page 17 - CHIMNEY OFFSET INSTALLATION

COMBUSTION AIR ASSEMBLY23MODEL AK-4 COMBUSTION AIR ASSEMBLY1. Remove the cover plate from the 4-inch outlet opening location on the left outside of th

Page 18 - FIGURE 19

24GAS APPLIANCE INSTALLATIONWARNING: Improper installation or operation of a gas appliance in this fireplace can allow unburned gas to leakout which

Page 19 - CHIMNEY CAP INSTALLATION

GAS APPLIANCE INSTALLATION257. Pack the insulation removed in step 4 around the pipe to prevent air flowing through the tube either into orout of the

Page 20 - 53D9035. Rev 1 03/03

COMBUSTIBLESURROUNDPLACEMENTCOMBUSTIBLE SURROUND MATERIALS COMBUSTIBLE SURROUND MATERIALS MAY BE PLACED INSIDE THE SHADED MAY BE PLACED INSIDE

Page 21 - IGURE 20

FIREPLACE OPERATIONWARNING: If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an openposition. (See addit

Page 22 - IGURE 21

FIREPLACE OPERATIONA FEW WORDS OF CAUTIONBeware of burning certain material in your fireplace. Among these are plastics, poison ivy twigs and stems,a

Page 23 - IGURE 22

1. Read these instructions entirely before beginning any part of the installation. Save these instructions forany future repairs.2. Use these instruc

Page 24 - COMBUSTION AIR ASSEMBLY

29MAINTENANCE AND SAFETYFUEL STORAGEWood can be dried sufficiently for burning within a few weeks if protected form rain in a low humidity area. It i

Page 25 - MPORTANT NOTICES:

FIREPLACE MAINTENANCEAt the end of each heating season or when the fireplace will not be in use for an extended time, the ashesshould be removed and t

Page 26 - IGURE 23

18. Do store your fuel supply at a distance equal to or greater than the spacing recommended for combustiblematerials from the fireplace.19. Do build

Page 27 - IGURE 24A

32PARTS DIAGRAM AND LISTFIGURE 2653D9035. Rev 1 03/03All repair part orders should be placed through your local dealer. To ensure prompt and accurate

Page 28 - FIREPLACE OPERATION

3353D9035. Rev 1 03/03PARTS DIAGRAM AND LISTFIGURE 27All repair part orders should be placed through your local dealer. To ensure prompt and accurate

Page 29

3453D9035. Rev 1 03/03FACTORY-BUILT FIREPLACE AND COMPONENTS(EXCEPT BLOWERS)WHAT IS COVERED AND FOR HOW LONG•FIVE-YEAR COVERAGE - For five years from

Page 30 - MAINTENANCE AND SAFETY

LIMITED WARRANTYYOUR DUTIESThis fireplace must be installed by a qualified installer according to your local building codes and installation instructi

Page 31

NOTES3653D9035. Rev 1 03/03

Page 32

NOTES3753D9035. Rev 1 03/03

Page 33 - IGURE 26

NOTES3853D9035. Rev 1 03/03

Page 34 - IGURE 27

53OPERATION GUIDELINESWhen a AK4 combustion air assembly and a combustion air duct are attached to the connecting point on theleft of the fireplace, c

Page 35 - IMITATIONS AND EXCLUSIONS

ATTENTIONAPPLIANCEINSTALLERPLEASE RETURN THESE OPERATINGAND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FORCONSUMER USE.53D9035. REV 1 03/03

Page 36 - OUR DUTIES

HWB700/HWB700HB MODELSINSTALLATION, OPERATION AND MAINTENANCE MANUALFOR RESIDENTIAL INSTALLATION53D9036. Rev 1 03/03THIS FIREPLACE IS U.L. LISTED FOR

Page 37

1You have chosen the finest wood burning fireplace available. Your fireplace has been designed foryears of heating and viewing enjoyment. Please tak

Page 38

1. Read these instructions entirely before beginning any part of the installation. Save these instructions forany future repairs.2. Use these instruc

Page 39

53OPERATION GUIDELINESWhen a AK4 combustion air assembly and a combustion air duct are attached to the connecting point on theleft of the fireplace, c

Page 40 - INSTALLER

64CLEARANCESRESIDENTIAL INSTALLATION53 3/8"53 3/8"MAINTAIN 2" MIN. AIR SPACEMAINTAIN 2" MIN. AIR SPACEBETWEEN CHIMNEY ANDBETWEE

Page 41 - HWB700/HWB700HB MODELS

CLEARANCES5NOTE: DIMENSIONS MAY VARY SLIGHTLY DUE TO MANUFACTURING TOLERENCES.NOTE: DIMENSIONS MAY VARY SLIGHTLY DUE TO MANUFACTURING TOLERENCES.4 5/1

Page 42

FIREPLACE LOCATIONCAUTION: Do not install fireplace over carpeting.This fireplace does not weigh more than large pieces of furniture and can normall

Page 43

8' 0"LEVEL SOLIDSURFACEFIRESTOP SPACER SEE NOTESJOIST INSULATE SAME AS CEILINGNOTES:1. MODEL LF-FS-2 FIRESTOP  SPACER MUS

Page 44

MULTIPLE STORY INSTALLATIONATTIC SPACESINGLE STORY INSTALLATION WITH POOR LOCATIONPREFERRED  LOCATION2" MIN. CLEARANCE 2" MIN. CLEARANC

Page 45 - CLEARANCES

64CLEARANCES53D9035. Rev 1 03/03

Page 46

9FLOOR PROTECTIONIf this fireplace is installed on a combustible floor, the floor area 20 inches in front of, and 12 inches either sideof the fireplac

Page 47 - FIREPLACE LOCATION

52 7/8"52 7/8"27"27"53 1/8"53 1/8"68"68"20"20" FLOOR FLOORCOMBUSTIBLE COMBUSTIBLE 26 3/8&quo

Page 48

1153D9036. Rev 1 03/03FIREPLACE COMPONENTSFIGURE 13

Page 49

FIREPLACE INSTALLATIONLOCATION SELECTIONUnpack and check the fireplace and chimney for damage. If any items have been damaged, report this to yourdea

Page 50 - IGURE 10

1353D9036. Rev 1 03/03CHIMNEY INSTALLATION1. Lay out, cut and frame openings through all ceilings and the roof at the point where the chimney will pas

Page 51

IMAGINARY IMAGINARYCENTER POINT CENTER POINT ACTUAL ACTUALCENTER POINTCENTER POINTCENTERLINE CENTERLINE OF CHIMNEYOF CHIMNEYPLUMB BOBP

Page 52 - IGURE 13

1553D9036. Rev 1 03/03CHIMNEY OFFSET INSTALLATIONELBOW INSTALLATIONThe following are important points that should be observed when installing elbows o

Page 53

CHIMNEY OFFSET AND CAP INSTALLATIONCHIMNEY HOUSINGINSTALL ROUND CHIMNEY CAP ORCONTINUE CHIMNEY TO PROPER HEIGHT ANDSTORM COLSTORM COLLARFLASHFLASHINGR

Page 54

1753D9036. Rev 1 03/03CHIMNEY CAP INSTALLATIONMODEL LC CHIMNEY CAPSPECIAL NOTE: The proper height as previously explained is important to assure prope

Page 55

CHIMNEY HEIGHT AND OFFSET CHARTS 17 17 26 1/2 26 1/2 31 3/4 31 3/4 36 36 41 1/4 41 1/4 47 1/4 47 1/4 50 3/4 50 3/4 57 3/4 57 3/4 62 6

Page 56

CLEARANCES553D9035. Rev 1 03/03

Page 57

1953D9036. Rev 1 03/03CHIMNEY CAP CHASE INSTALLATIONThe preinstalled chimney sections should be no more than 13 inches below the top of the chase. Th

Page 58

OUTSIDE COMBUSTION AIR PRECAUTIONS & RECOMMENDATIONSCONCRETE SLAB INSTALLATION  (OPTIONAL OUTSIDE AIR RUNS)INLET GRILLE IN SOFFIT(OVERHANG)8&

Page 59 - 53D9036. Rev 1 03/03

2153D9036. Rev 1 03/03OUTSIDE COMBUSTION AIR PRECAUTIONS & RECOMMENDATIONSOUTSIDE COMBUSTION AIR RECOMMENDATIONS (CONTINUED)1. Extremely long run

Page 60

COMBUSTION AIR ASSEMBLYMODEL AK-4 COMBUSTION AIR ASSEMBLY1. Remove the cover plate from the 4-inch outlet opening location on the left outside of the

Page 61

2353D9036. Rev 1 03/03GAS APPLIANCE INSTALLATIONWARNING: Improper installation or operation of a gas appliance in this fireplace can allow unburned g

Page 62

GAS APPLIANCE INSTALLATION7. Pack the insulation removed in step 4 around the pipe to prevent air flowing through the tube either into orout of the fi

Page 63

2553D9036. Rev 1 03/03COMBUSTIBLESURROUNDPLACEMENTCOMBUSTIBLE SURROUND MATERIALS COMBUSTIBLE SURROUND MATERIALS MAY BE PLACED INSIDE THE SHADED

Page 64

FIREPLACE OPERATIONWARNING: If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an openposition. (See addit

Page 65

2753D9036. Rev 1 03/03FIREPLACE OPERATIONA FEW WORDS OF CAUTIONBeware of burning certain material in your fireplace. Among these are plastics, poison

Page 66 - IGURE 26A

MAINTENANCE AND SAFETYFUEL STORAGEWood can be dried sufficiently for burning within a few weeks if protected form rain in a low humidity area. It isf

Page 67

6CLEARANCES53D9035. Rev 1 03/03

Page 68

2953D9036. Rev 1 03/03FIREPLACE MAINTENANCEAt the end of each heating season or when the fireplace will not be in use for an extended time, the ashess

Page 69

18. Do store your fuel supply at a distance equal to or greater than the spacing recommended for combustiblematerials from the fireplace.19. Do build

Page 70

3153D9036. Rev 1 03/03PARTS DIAGRAM AND LISTFIGURE 26All repair part orders should be placed through your local dealer. To ensure prompt and accurate

Page 71

3253D9036. Rev 1 03/03PARTS DIAGRAM AND LISTFIGURE 27All repair part orders should be placed through your local dealer. To ensure prompt and accurate

Page 72

3353D9036. Rev 1 03/03FACTORY-BUILT FIREPLACE AND COMPONENTS(EXCEPT BLOWERS)WHAT IS COVERED AND FOR HOW LONG•FIVE-YEAR COVERAGE - For five years from

Page 73

3453D9036. Rev 1 03/03LIMITED WARRANTYYOUR DUTIESThis fireplace must be installed by a qualified installer according to your local building codes and

Page 74

ATTENTIONAPPLIANCEINSTALLERPLEASE RETURN THESE OPERATINGAND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FORCONSUMER USE.53D9036. REV 1 03/03

Page 75

FIREPLACE LOCATIONCAUTION: Do not install fireplace over carpeting.This fireplace does not weigh more than large pieces of furniture and can normall

Page 76

8' 0"LEVEL SOLIDSURFACEFIRESTOP SPACER SEE NOTESJOIST INSULATE SAME AS CEILINGNOTES:1. MODEL LF-FS-2 FIRESTOP  SPACER MUS