MODELS:
BBV400 SBV400 SBV500
B-VENT SERIES
NATURAL VENT GAS FIREPLACE
WARNINGS
IF THE INFORMATION IN THESE INSTRUCTIONS ARE
NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: Improper installation, adjustment,
alteration, services or maintenance can cause injury or
property damage. Refer to this manual. For assistance
or additional information consult a qualified installer,
service agency or the gas supplier.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
CHILDREN A N D ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURE AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
Y O U N G C H I L D R E N S H O U L D B E
SUPERVISED WHEN THEY ARE IN THE
SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
KEEP THE ROOM AREA CLEAR AND
FREE FROM COMBUSTIBLE MATERIALS,
GASOLINE, AND OTHER FLAMMABLE
VAPORS AND LIQUIDS.
READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS
INSTALLATION AND OPERATING
INSTRUCTIONS
Page view 0
1 2 3 4 5 6 ... 41 42

Summary of Contents

Page 1 - B-VENT SERIES

MODELS: BBV400 SBV400 SBV500B-VENT SERIES NATURAL VENT GAS FIREPLACE WARNINGSIF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A

Page 2 - CONTENTS

10 62D4036PRE-INSTALLATION INFORMATION FIREPLACE LOCATIONPlan for the installation of your appliance. This includes determining where the unit is to

Page 3 - IMPORTANT SAFETY INFORMATION

62D4036 1112"MaximumDepth8" Minimum72" MinimumMinimum 3"From BothSide Wallsto OpeningFollow these instructions carefully to

Page 4

12 62D4036The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6 . Use two (2) wood screws or masonry/ concrete screws

Page 5 - CODE APPROVAL

62D4036 13Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property d

Page 6 - PRE-INSTALLATION INFORMATION

14 62D4036B-VENT PIPE SIZING BBV400/400BBV SBV400/400SBV SBV500/500SBV4" 6" 6"VENT INSTALLATION INSTALLATION PLANNING “B” VENT PIPESee

Page 7

62D4036 15Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitu

Page 8 - FIREPLACE DIMENSIONS

16 62D40368' MaximumOUTSIDE COMBUSTION AIR PRECAUTIONS AND RECOMMENDATIONS Note: The use of outside air for combustion is optional unless req

Page 9 - SBV400 and SBV500

62D4036 17COMBUSTION AIR ASSEMBLY MODEL OAC-4 COMBUSTION AIR ASSEMBLY1. Remove the cover plate from the 4" outlet opening location on the left

Page 10 - FIREPLACE LOCATION

18 62D4036Figure 16 - External Regulator with Vent Pointing Down (Propane/LP Only)Use only new black iron or steel pipe. Internally tinned copper

Page 11 - CLEARANCES

62D4036 193"MinimumFIREPLACE INSTALLATION A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8&q

Page 12 - 2" Nail

2 62D4036CONTENTSImportant Safety Information ... 3Product Features ... 5Code Appro

Page 13 - VENT INSTALLATION

20 62D4036CHECKING GAS PRESSURE1. Check gas type. The gas supply must be the same as stated on the applianceʼs rating decal. If the gas supply is d

Page 14

62D4036 21ONOFFOPTIONAL REMOTEWALL SWITCHONOFFOPTIONAL REMOTEWALL SWITCHPILOT HILOONOFFTHTPTH/TPONOFFSPILLSWITCHRSREMOTE WALL MOUNTED SWITCHA remote

Page 15

22 62D4036ELECTRICAL INSTALLATION ELECTRONIC PILOT IGNITION WIRINGDo not connect 110-120 VAC to the Remote Wall Switch. The appliance will malfuncti

Page 16 - 8' Maximum

62D4036 23Flat AreaFINAL INSTALLATION LOG PLACEMENT1. Place rear log (#1) on grate assembly. Log should rest firmly on the two log mounting pins

Page 17 - COMBUSTION AIR ASSEMBLY

24 62D4036A. This appliance is equipped with a pilot which must be lit with an ignitor while following these instructions exactly.B.

Page 18 - FIREPLACE INSTALLATION

62D4036 25PILOTOFFPILOTONContinued on next page OPERATING INSTRUCTIONSAPPROVED LEAK TESTING METHOD You may check for gas leaks with the following met

Page 19 - CAUTION

26 62D403650PILOTOFFPILOTONOFFPILOTONPILOTFigure 25 - On Position PILOTOFFPILOTONFigure 24 - On/Off/RS Switch OPERATING INSTRUCTIONS LIGHTING BURNER

Page 20 - CHECKING GAS PRESSURE

62D4036 27ONOFFPILOTLOHIFigure 28 - Electronic Gas Valve OPERATING INSTRUCTIONS LIGHTING ELECTRONIC IGN 1. STOP! Read the safety information above

Page 21 - WARNING

28 62D4036Figure 29 - Pilot Flame Thermopile Thermocouple Turn off gas before servicing fireplace. It is recommended that a qualified servi

Page 22

62D4036 29CLEANING AND MAINTENANCE VENT SYSTEMThe fireplace and venting system should be inspected before initial use and at least annually by a quali

Page 23 - FINAL INSTALLATION

62D4036 34. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are le

Page 24 - OPERATING INSTRUCTIONS

30 62D40361234a4b4c576ILLUSTRATED PARTS LISTSFIREBOX COMPONENTS

Page 25 - LIGHTING PILOT

62D4036 31FIREBOX COMPONENTS ILLUSTRATED PARTS LISTS Item Description Qty BBV400/400BBV SBV400/400SBV SBV500/500SBV1 Pull Screen Panel 2 61D0001 61D0

Page 26

32 62D4036ILLUSTRATED PARTS LISTS123456781012, 13STANDING PILOT — MILLIVOLT CONTROL2T2I2C911

Page 27

62D4036 33ILLUSTRATED PARTS LISTS STANDING PILOT – MILLIVOLT CONTROLItem Description Qty BBV400NV BBV400PV SBV400NV SBV400PV SBV500NV SBV500PV1 Gas V

Page 28 - CLEANING AND MAINTENANCE

34 62D4036ILLUSTRATED PARTS LISTS12345679ELECTRONIC IGNITION 8101112

Page 29

62D4036 35ELECTRONIC IGNITION ILLUSTRATED PARTS LISTSItem Description QtyBBV400NV BBV400PV SBV400NV SBV400PV SBV500NV SBV500PV1Gas Valve Assembly137D

Page 30 - ILLUSTRATED PARTS LISTS

36 62D4036STANDING PILOT IGNITIONTROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION1. Spark ignitor will not light pilot after repeated trig-gering of pi

Page 31

62D4036 37ELECTRONIC IGNITIONTROUBLESHOOTING START1. Turn gas supply off.2. Turn ON/OFF switch to “ON” Power to module (24V Normal)YES Is there

Page 32

38 62D4036TROUBLESHOOTING GENERAL TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION1. Glass Soots A. Flame impingement on logs A. Install log set per

Page 33

NOTE REGARDING VENTED PRODUCTSThis product must be installed by a licensed plumber or gas fi tter when installed within the Commonwealth of Massachuset

Page 34

4 62D4036IMPORTANT SAFETY INFORMATIONContinued from page 312. Do not use this fireplace to cook food or burn paper or other objects.13. Never place

Page 35

SPECIAL REQUIREMENTS CONTINUED2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accor-dance with the above provisi

Page 37

September 2006

Page 38

62D4036 5PRODUCT FEATURES AND CODE APPROVAL Figure 1 - BBV/SBV Fireplace • This appliance has been certified for use with either natural or propane

Page 39 - SPECIAL REQUIREMENTS

6 62D4036PRE-INSTALLATION INFORMATIONINSTALLING ABOVE 2000 FEET• In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elev

Page 40

62D4036 7BAHGDFEAC1/2" or5/8"CAGCGAPRE-INSTALLATION INFORMATION FIREPLACE FRAMING Firebox framing can be built before or after the applianc

Page 41 - 62D4036 39

8 62D4036313/8"4"B-Vent6"34"1/2" or 5/8"Drywall Spacers14"8"211/2"95/8"Air Kit23/16"1/2"

Page 42 - Paris, Kentucky 40361

62D4036 9A6"B-Vent6"34"1/2" or 5/8"Drywall Spacers21"137/16"211/2"163/4"95/8"Air Kit1/2" or 5/