Monessen Hearth ILDV20NV Operations Instructions

Browse online or download Operations Instructions for Fireplaces Monessen Hearth ILDV20NV. Monessen Hearth ILDV20NV Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Models: ILDV20NV & ILDV20PV
ILDV30NV & ILDV30PV
ILDV Series
Direct Vent
Gas Fireplace Insert
READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC AND AWAY FROM FURNITURE AND
DRAPERIES.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURE AND SHOULD
STAY AWAY TO AVOID BURNS OR CLOTHING
IGNITION.
YOUNG CHILDREN SHOULD BE SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS THE
APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
KEEP THE ROOM AREA CLEAR AND
FREE FROM COMBUSTIBLE MATERIALS,
GASOLINE, AND OTHER FLAMMABLE
VAPORS AND LIQUIDS.
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
WARNING: Improper installation, adjustment, alteration,
services or maintenance can cause injury or property
damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency
or the gas supplier.
This appliance may be installed in an aftermarket*,
permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
* Aftermarket: Completion of sale, not for purpose of resale, from the
manufacturer.
WARNING
83D0511 12/08 Rev. 2
Installation and Operating Instructions
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Gas Fireplace Insert

Models: ILDV20NV & ILDV20PV ILDV30NV & ILDV30PVILDV Series Direct Vent Gas Fireplace InsertREAD BEFORE INSTALLING. SAVE THESE INSTRUCTIONSD

Page 2 - CONTENTS

10 83D0511ILDV30/ILDV20 Fireplace InsertINSTALLATIONINSERT PLACEMENT• The insert must be placed within a code-conforming masonry fireplace or a tested

Page 3 - IMPORTANT SAFETY INFORMATION

83D0511 11ILDV30/ILDV20 Fireplace InsertINSTALLATION ZERO-CLEARANCE (METAL) FIREPLACE REQUIREMENTS• The damper and grate must be removed.• The smoke

Page 4

12 83D0511ILDV30/ILDV20 Fireplace InsertVENT INSTALLATION Read all instructions completely and thoroughly before attempting installation. Failure to

Page 5 - CODE APPROVAL

83D0511 13ILDV30/ILDV20 Fireplace InsertVENT INSTALLATION WARNING• Make sure the exhaust pipe on heater connects to exhaust portion of cap. Attach fl

Page 6 - PRE-INSTALLATION INFORMATION

14 83D0511ILDV30/ILDV20 Fireplace InsertVENT INSTALLATION ALTITUDE CONSIDERATIONSThis heater has been tested at altitudes ranging from sea level to 4

Page 7 - INSERT DIMENSIONS

83D0511 15ILDV30/ILDV20 Fireplace InsertVENT INSTALLATION VENT CONFIGURATIONSExhaustExhaustInletRecommended block-off plate (noncombustible metal). P

Page 8 - 8 83D0511

16 83D0511ILDV30/ILDV20 Fireplace InsertVENT INSTALLATION MANIFOLD REMOVAL AND INSTALLATIONThe manifold is shipped attached to insert. It may be remo

Page 9 - CLEARANCES

83D0511 17ILDV30/ILDV20 Fireplace InsertINSERT INSTALLATIONCHECK GAS TYPEUse proper gas type for the insert you are installing. If you have conflictin

Page 10 - INSTALLATION

18 83D0511ILDV30/ILDV20 Fireplace InsertINSERT INSTALLATION WARNINGOnly persons licensed to work with gas piping may make the necessary gas con-necti

Page 11 - Internal

83D0511 19ILDV30/ILDV20 Fireplace InsertCHECKING GAS PRESSURE1. Check gas type. The gas supply must be the same as stated on the appliance’s rating d

Page 12 - 12 83D0511

2 83D0511ILDV30/ILDV20 Fireplace InsertCONTENTSImportant Safety Information ... 3Product Features ...

Page 13 - VENT REQUIREMENTS

20 83D0511ILDV30/ILDV20 Fireplace InsertELECTRICAL INSTALLATIONREMOTE WALL MOUNTED SWITCHA remote wall switch and up to fifteen (15) feet of 18 Ga. wi

Page 14 - High Temp

83D0511 21ILDV30/ILDV20 Fireplace InsertLOG PLACEMENTBefore you begin - This unit is supplied with six (6) ceramic fiber logs. Do not handle these log

Page 15

22 83D0511ILDV30/ILDV20 Fireplace InsertLOG PLACEMENT Log #1LG538Figure 18Place Log #1Log #2Figure 19Place Log #2LG539Log #6LG537Figure 17Place Log #

Page 16

83D0511 23ILDV30/ILDV20 Fireplace InsertLOG PLACEMENTLog #3LG540Figure 20Place Log #3Log #4Figure 21Place Log #4LG541Log #5LG542Figure 22Place Log #5

Page 17 - INSERT INSTALLATION

24 83D0511ILDV30/ILDV20 Fireplace InsertSURROUND INSTALLATION INSTALL SURROUND1. Remove glass door assembly. Page 29, Figure 342. Align cast or bev

Page 18 - 3" Minimum

83D0511 25ILDV30/ILDV20 Fireplace InsertA. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following the

Page 19 - CHECKING GAS PRESSURE

26 83D0511PILOTOFFPILOTONILDV30/ILDV20 Fireplace InsertContinued on next page APPROVED LEAK TESTING METHOD You may check for gas leaks with the follo

Page 20 - ELECTRICAL INSTALLATION

83D0511 27ILDV30/ILDV20 Fireplace InsertOPERATING INSTRUCTIONS PILOTOFFPILOTONFigure 30 - Off Position OFFPILOTONPILOTPILOTOFFPILOTONONOFF LIGHTING

Page 21 - LOG PLACEMENT

28 83D0511ILDV30/ILDV20 Fireplace InsertAIR SHUTTER ADJUSTMENT (NATURAL GAS ONLY)ADJUST THE AIR SHUTTERThe venturi of the burner is equipped with an

Page 22

83D0511 29ILDV30/ILDV20 Fireplace InsertGLASS FRAME REMOVALWARNINGMake sure the glass panel edges donot touch any metal parts during thermal expansio

Page 23

83D0511 3ILDV30/ILDV20 Fireplace Insert • do not touch any electrical switch; do not use any phone in your building . • immediately call your

Page 24 - SURROUND INSTALLATION

30 83D0511ILDV30/ILDV20 Fireplace InsertBLOWER REMOVAL and ASSEMBLYBLOWER REPLACEMENTTurn off the unit and allow to cool completely. Turn off gas at

Page 25 - OPERATING INSTRUCTIONS

83D0511 31ILDV30/ILDV20 Fireplace InsertBLOWER REMOVAL and ASSEMBLYBLOWER PARTS LIST:CAUTIONLabel all wires prior to disconnection when servicing con

Page 26 - LIGHTING PILOT

32 83D0511ILDV30/ILDV20 Fireplace InsertMake sure the gas valve knob is in the “OFF” position. Wait at least five (5) minutes before start-ing mainten

Page 27 - TO TURN OFF GAS

83D0511 33ILDV30/ILDV20 Fireplace InsertCLEANING and MAINTENANCEFIREBOX CLEANING1. Carefully remove log set, and embers from combustion chamber. 2.

Page 28 - ADJUST THE AIR SHUTTER

34 83D0511ILDV30/ILDV20 Fireplace InsertMAINTENANCEYEARLY SERVICE PROCEDUREFailure to inspect and maintain heater may lead to improper combustion and

Page 29 - GLASS FRAME REMOVAL

83D0511 35ILDV30/ILDV20 Fireplace InsertREPLACEMENT PARTS12/13246123457101114151718192022162321232526272889

Page 30 - BLOWER REMOVAL and ASSEMBLY

36 83D0511ILDV30/ILDV20 Fireplace InsertREPLACEMENT PARTS ILDV20NV ILDV20PV ILDV30NV ILDV30PV Item Description Qty. Natural Propane Natural

Page 31

83D0511 37ILDV30/ILDV20 Fireplace InsertTROUBLESHOOTINGOBSERVED PROBLEMPiezo ignitor will not light the pilot after repeated pressing of piezo ignito

Page 32 - CLEANING and MAINTENANCE

38 83D0511ILDV30/ILDV20 Fireplace InsertNOTES

Page 33

83D0511 39ILDV30/ILDV20 Fireplace InsertLIMITED LIFETIME WARRANTY POLICYLIFETIME WARRANTYThe following components are warranted for life to the origi

Page 34 - MAINTENANCE

4 83D0511ILDV30/ILDV20 Fireplace InsertIMPORTANT SAFETY INFORMATIONContinued from page 310. Have venting system inspected annually by a quali-fied ser

Page 35 - REPLACEMENT PARTS

40 83D0511ILDV30/ILDV20 Fireplace InsertDECEMBER 2008 83D0511 • Rev. 2MHSC149 Cleveland Drive • Paris, Kentucky 40361www.mhsc.comEfficiency Ratings M

Page 36

83D0511 5ILDV30/ILDV20 Fireplace InsertPRODUCT FEATURES AND CODE APPROVAL • This appliance has been certified for use with either natural or pro-pan

Page 37 - TROUBLESHOOTING

6 83D0511ILDV30/ILDV20 Fireplace InsertPRE-INSTALLATION INFORMATIONHIGH ELEVATIONSInput ratings are shown in BTU per hour and are certified without de

Page 38 - 38 83D0511

83D0511 7ILDV30/ILDV20 Fireplace InsertINSERT DIMENSIONSIHGJKLCDFEABFigure 2 ILDV Fireplace Insert Dimensions ILDV20 ILDV30 A 211/4" 251/4"

Page 39 - 83D0511 39

8 83D0511ILDV30/ILDV20 Fireplace InsertGENERAL INSTALLATION INFORMATION WARNINGThe dimensions shown on Pages 9 and 10, Figures 3 and 4, are minimum

Page 40 - Efficiency Ratings

83D0511 9ILDV30/ILDV20 Fireplace InsertCLEARANCESINSERT CLEARANCESNo combustibles (ie: drapes, doors) may be within, or swing within 36" of the

Comments to this Manuals

No comments