FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT
8'max.
COMBUSTION AIR
1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner.
Locate assembly amin. of 12" above the snow line to prevent blockage by snow accumulation.
2. Never
mount the combustion air inlet assembly in a garage or storage area where combustible fumes such as gasoline
might be drawn into the replace.
3. Combustion air can be drawn from the crawl space under a house when an adequate supply of air is provided by open
ventilation.
4. CAUTION: Do not take combustion air from attic space or garage space.
5. locate air supply at least 3' away from any appliance vent terminal.
6.
Avoid extremely long runs and numerous turns in the duct leading from the replace to the combustion air assembly.
These conditions increase the resistance to the free ow of air through the duct. See Figures 29 through 32 for methods
of installing the outside air for combustion assemblies.
Figure 29 - Basement Installation
Figure 30 - Concrete Slab Installation
(Optional Outside Air Runs)
Above
Snow
Level
Ground
Level
Basement
Wall
Inlet Grill in
Soffit
(Overhang)
Figure 32 - 45° Corner Installation on Slab
Floor
Figure 31 - Installation Above Basement or Crawl
Space
Inside Wall
Outside
Wall
Duct Extended
to Miss Joist
To Outside Wall
Note: Fireplace model in illustrations may not be representative of your appliance.