Monessen Hearth GPF36 Operations Instructions Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
24 43D0121
MODEL AK-4 COMBUSTION AIR ASSEMBLY (CONTINUED)
7. If the duct is the insulated type, push the insulation back from one end of
the duct approximately 2".
See Figure 36.
8. Slip the exposed end of the duct over the starting collar on the replace
.
9. Using the sheet metal screws provided, secure the duct end to the collar
attached to the replace.
10. Nail or screw the combustion air assembly to the surface of the wall.
Note: If the wall covering is brick or stone, use appropriate masonry
fasteners. If necessary, splice the duct. Use a model 403-duct connector to
splice duct sections.
INSTALLING MODEL 403 DUCT CONNECTOR
1. Push insulation back approximately 2" from the end of each duct.
2. Slip each duct over duct connector until an equal length of connector extends into each duct.
3. Place
duck clamp over the end of each duct. Tighten duct clamp down snuggly.
4. Push insulation back into place and over duct clamp.
Figure 36 - Installing Duct Connector 403
Approximately
2"
Insulation
Duct
Connector
Duct Clamp
FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT